SC Tables
SM 6-23 D117/D118
Troubleshooti
ng
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
498 C
Temperature and humidity sensor error
The thermistor output of the temperature sensor was not within the
prescribed range (more than 0.76V to less than 2.90V).
The thermistor output of the humidity sensor was not within the
prescribed range (2.4V or more).
Temperature and humidity sensor harness disconnected, loose,
defective
Temperature and humidity sensor defective
1. Check the connector and harness.
2. Replace the temperature and humidity sensor.