ng
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
541 A
Heating roller thermopile error
The temperature detected by the heating roller thermopile does not
reach 0°C within the prescribed time for 10 consecutive times.
Loose connection of the heating roller thermopile
Defective heating roller thermopile
Defective thermopile
1. Check if the heating roller thermopile is firmly connected.
2. Replace the heating roller thermopile.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
542
-02
-03
A
Heating roller thermopile reload error
The heating roller temperature does not reach 80°C within the
prescribed time.
The center temperature of the heating roller does not reach the
target reload permit temperature within the prescribed time.
The center temperature of the heating roller does not reach the
target temperature after starting the heater control in warm up with
low temperature.
Dirty or defective thermopile lenses
Defective thermistor
Input voltage out of specification (out of warranty)
1. Check and clean the thermopile lenses.
2. Check if the heating roller thermopile is firmly connected.
3. Replace the thermopile.