Test pattern check Possible cause/Countermeasure
The sub scan registrations of M,
C, Y, K are shifted by more than
±20.
Defective image transfer belt
Defective drive units
Defective BICU
1. Replace the image transfer belt.
2. Replace the drum motor.
3. Replace the BICU.
The main scan registration is
shifted by more than ±0.66 mm,
but only at the central area of the
image on the output.
Defective ID sensor at center
Deformed center area on the image transfer belt
Defective BICU
1. Replace the ID sensor.
2. Replace the image transfer belt.
3. Replace the BICU.
The skew for M, C, Y, K is more
than ±0.75 mm.
Defective PCDU
Defective laser optics housing unit
Defective BICU
1. Perform the color skew adjustment (
p.4-3).
2. Reinstall or replace the PCDU.
3. Replace the laser optics housing unit.
4. Replace the BICU.
Others
Skew correction upper limit error
Defective BICU
Defective laser optics housing unit
1. Perform the color skew adjustment (
p.4-3).
2. Replace the BICU.
3. Replace the laser optics housing unit.
After Executing SP2-111-003
Result: "1" in SP2-194-007
Result: "0" in SP2-194-010, -011, -012, -013