Troubleshooting Guide
D117/D118 6-86 SM
Test pattern check Possible cause/Countermeasure
Others Skew correction upper limit error
Defective BICU
Defective laser optics housing unit
1. Replace the BICU.
2. Perform the color skew adjustment (
p.4-3).
3. Replace the laser optics housing unit.
After Executing SP2-111-001
Result: "0" in SP2-194-007
Result: Color registration errors in SP2-194-010, -011, -012, -013
Test pattern check Possible cause/Countermeasure
Low image density on the output Low pattern density
Do the forced process control (SP3-011-001) or
supply some toner (SP3-030-xxx).
The main scan registration is
shifted, but only at the central
area of the image on the output.
Defective ID sensor at center
Deformed center area on the image transfer belt
Defective BICU
1. Replace the ID sensor.
2. Replace the image transfer belt.
3. Replace the BICU.
The main scan registrations of M,
C, Y, K are shifted.
Defective laser optics housing unit
Defective ID sensor
Defective BICU
Incorrect SP value
1. Perform the color skew adjustment (
p.4-3).
2. Replace the laser optics housing unit.
3. Replace the ID sensor.
4. Replace the BICU.
5. Adjust the value with SP2-182-004 to -021.

Table of Contents