Main SP Tables-3
SM Appendix 3-201 D117/D118
Appendix:
SP Mode
Tables
040 Initial ProCon Thresh *ENG
Sets process control flag and executes
process control by determining the high
image coverage is successive if the
cumulative average (M) of image
coverage (SP3224-009 to 012) is more
than the specified value.
[0 to 255 / 6 / 1times/step]
041 High Coverage Thresh:H *ENG
This SP is referenced when an output of
high image coverage.
[0 to 100 / 60 / 1%/step]
050 ProCon Thresh *ENG [0 to 255 / 14 / 1times/step]
060 Low Coverage Thresh *ENG
This SP is referenced when an output of
low image coverage.
[0.0 to 20.0 / 3.0 / 0.1%/step]
070
TC Upper Limit
Correction
*ENG
Sets Vtref lower limit (TC upper limit)
which can be canceled temporarily by
determining the low image coverage is
successive if the cumulative average (L)
of image coverage (SP3224-013 to 016)
is less than the specified value.
[0.0 to 5.0 / 0.5 / 0.1wt%/step]
071
TC Upper
Limit:Display:Bk
*ENG
Displays Vtref lower limit (TC upper limit)
which can be canceled temporarily by
determining the low image coverage is
successive if the cumulative average (L)
of image coverage (SP3224-013 to 016)
is less than the specified value.
[1.0 to 15.0 / - / 0.1wt%/step]
072 TC Upper Limit:Display:C *ENG
073 TC Upper Limit:Display:M *ENG
074 TC Upper Limit:Display:Y *ENG