temperature detected error (hardware)
occurred.
Resets the LD driver parameters written
to the EEPROM on the EGB.
Displays the current temperature (°C) at
the fusing thermopile.
Displays the current temperature (°C) at
the fusing NC sensor.
Displays the current temperature (°C) at
the pressure roller thermistor (center).
Displays the current temperature (°C) at
the pressure roller thermistor (end).
Switches continuous print mode.
[0 (Fusing Priority) / 1 (Productivity
Priority) / 2 (Normal Mode)]
Sets target fusing temperature for Energy
Save Mode.
Sets the target fusing temperature (°C) of
Line Speed 1 for each paper type and
printing mode.
• Thin
• Plain1
• Plain2
• Middle Thick
• Recycle
Sets the target fusing temperature (°C) of
Line Speed 3 for each paper type and
printing mode.
• Thin
• Plain1
• Plain2
• Middle Thick