5.System Maintenance
131
Menu
Description
This calibrates the motor speed to match
the length of the new transfer belt.
Fuser SC
Detect
Fus. Jam Dete.
Determines whether or not the SC code
is issued after three successive jams in
the fusing unit.
[0 (OFF) or 1(ON)]
SC Number
Displays the SC number occurred.
Temp.occurred
Heat Center
Displays the temperature (°C) at the
fusing thermopile when the fusing related
SC occurred.
Heat NC
Displays the temperature (°C) at the
fusing NC sensor when fusing related SC
occurred.
Press Center
Displays the temperature (°C) at the
pressure roller thermistor (center) when
fusing related SC occurred.
Press Left
Displays the temperature (°C) at the
pressure roller thermistor (end) when
fusing related SC occurred.
Press Right
(Reserved)
Temp.bf 1Cyc
Heat Center
Displays the temperature (°C) of each
sensor at the occurrence of the 1st fusing
SC code before the current SC code.
Heat NC
Press Center
Press Left
Press Right
Temp.bf 2Cyc
Heat Center
Displays the temperature (°C) of each
sensor at the occurrence of the 2nd
fusing SC code before the current SC
code.
Heat NC
Press Center
Press Left
Press Right
Temp.bf 3Cyc
Heat Center
Displays the temperature (°C) of each
sensor at the occurrence of the 3rd
fusing SC code before the current SC
code.
Heat NC
Press Center
Press Left
Press Right
Fuser SC
Reset
Fusing SC Reset
Resets the fusing related SC.
Hard High Temp. Dete.
Resets the fusing related SC when high-

Table of Contents