EasyManua.ls Logo

Rockwell Automation Allen-Bradley 2094-BM01-S - Page 155

Rockwell Automation Allen-Bradley 2094-BM01-S
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010 155
Configure and Start Up the Kinetix 6000 Drive System Chapter 6
Parameters begin with a variable to identify a specific axis by slot number, as
follows:
IAM module = 0 for parameters 0…999
1st AM module = 1 for parameters 1000…1999
2nd AM module = 2 for parameters 2000…2999 and so on
7th AM module = 7 for parameter 7000…7999
Table 82 - Monitor System Variables
The value entered in Scale Parameter will scale the analog output so that you can
get a full scale reading of the specific parameter for the dynamic range or values
you are testing.
For linear scaling specifications, refer to the table on page 65
.
Table 83 - Monitor Dynamic System Variables
Analog
Output
Controlling Parameter Scale Parameter
Parameter Number
(1)
Default Value
(1)
Parameter Number
(1)
Default Value
1 x681 xx40 x682 0.0060
2 x683 xx84 x684 0.1000
(1) x = slot number
Attribute
Parameter Number
(1)
(1) x = slot number.
Velocity feedback xx40
Velocity commanded xx36
Torque feedback xx84
Torque commanded xx80

Table of Contents

Related product manuals