DC Common Bus Applications Appendix D
Calculate Additional Bus
Capacitance
Additional bus capacitance is the sum of all follower IAM and AM module
capacitance values for your Bulletin 2094 common-bus modules. Specifically, this
includes the capacitance values for each of these modules.
Each follower IAM (converter and inverter) module
Each AM module on the follower IAM module power rail
Enter the additional bus capacitance value in step 6
of Set the Additional Bus
Capacitance Parameter.
Bulletin 2094 Drive
Capacitance Values
Use these tables when calculating total bus capacitance and additional bus
capacitance for your Bulletin 2094 common-bus application.
Table 125 - IAM/AM (230V) Modules
Table 126 - IAM/AM (460V) Modules
Table 127 - Shunt Module (230/460V)
IAM Converter (230V)
Capacitance
µF
AM Inverter (230V)
Capacitance
µF
2094-AC05-MP5-x
270
2094-AMP5-x 390
2094-AC05-M01-x 2094-AM01-x 660
2094-AC09-M02-x 540 2094-AM02-x 780
2094-AC16-M03-x 1320 2094-AM03-x 1320
2094-AC32-M05-x 1980 2094-AM05-x 2640
IAM Converter (460V)
Capacitance
µF
AM Inverter (460V)
Capacitance
µF
2094-BC01-MP5-x
110
2094-BMP5-x 75
2094-BC01-M01-x 2094-BM01-x 150
2094-BC02-M02-x 220 2094-BM02-x 270
2094-BC04-M03-x 940 2094-BM03-x 840
2094-BC07-M05-x 1410 2094-BM05-x 1175
SM (230-460V)
Capacitance
µF
2094-BSP2 470