Rockwell Automation Publication 2094-UM001D-EN-P - May 2010 189
Specifications and Dimensions Appendix A
Power Dissipation
Specifications
Use this table to size an enclosure and calculate required ventilation for your
Kinetix 6000 drive system.
Power dissipation specifications are based on these calculations. For example:
2094-BC02-M02-x with 4.52 A
dc
(=20%) converter DC current and 10.3 A
rms
(=100%) inverter output current.
Converter loss (36 W) + Inverter loss (142 W) = 178 W total power dissipation.
Kinetix 6000
(1)
Drive Modules
Usage as % of Rated Power Output
(watts)
20% 40% 60% 80% 100%
IAM (converter) module
(2)
2094-AC05-MP5-x 8 11151924
2094-AC05-M01-x 9 12162025
2094-AC09-M02-x 14 20 28 36 46
2094-AC16-M03-x 19 30 43 58 74
2094-AC32-M05-x 41 68 100 136 176
2094-BC01-MP5-x
18 21 25 29
34
2094-BC01-M01-x 33
2094-BC02-M02-x 36 44 54 64 75
2094-BC04-M03-x 50 67 87 110 135
2094-BC07-M05-x 71 101 137 179 226
IAM (inverter) module or AM module
(2)
2094-AC05-MP5-x or 2094-AMP5-x 28 32 37 41 46
2094-AC05-M01-x or 2094-AM01-x 31 38 46 54 62
2094-AC09-M02-x or 2094-AM02-x 34 45 57 70 84
2094-AC16-M03-x or 2094-AM03-x 48 68 91 116 144
2094-AC32-M05-x or 2094-AM05-x 104 156 212 274 342
2094-BC01-MP5-x or 2094-BMP5-x 46 54 61 69 77
2094-BC01-M01-x or 2094-BM01-x 57 73 90 108 126
2094-BC02-M02-x or 2094-BM02-x 53 72 93 116 142
2094-BC04-M03-x or 2094-BM03-x 94 130 169 211 255
2094-BC07-M05-x or 2094-BM05-x 121 183 252 326 407
Shunt module
2094-BSP2 68 121 174 227 280
(1) Power dissipation for the Bulletin 2094 control modules, catalog numbers 2094-SE02F-M00-Sx and 2094-EN02D-M01-Sx, is included in the IAM and AM power module
specifications.
(2) Internal shunt power is not included in the calculations and must be added based on utilization.