Rockwell Automation Publication 2094-UM001D-EN-P - May 2010 177
Removing and Replacing the Kinetix 6000 Drive Modules Chapter 8
Replace the Power Rail
This procedure assumes you do not need to change the location of the power rail
on the panel and you intend to reuse the mounting bolts of the power rail you just
removed.
Follow these steps to replace the power rail.
1. Align the replacement power rail over the existing mounting bolts.
2. Tighten the mounting bolts.
3. Reattach the braided grounding strap to the power rail grounding stud
(refer to page 176
).
IMPORTANT
If you need to change the location of the power rail, or if you are
installing a power rail designed for additional or fewer modules than you
removed, refer to Kinetix 6000 Power Rail Installation Instructions,
publication 2094-IN003
.
ATTENTION: To avoid damage to the power rail during installation, do
not remove the protective boots until the module for each slot is ready for
mounting.
IMPORTANT
To improve the bond between the power rail and subpanel,
construct your subpanel out of zinc plated (paint-free) steel.