Rockwell Automation Publication 2094-UM001D-EN-P - May 2010 47
Chapter
3
Mounting the Kinetix 6000 Drive System
Introduction
This chapter provides the system installation procedures for mounting your
Kinetix 6000 drive components on the Bulletin 2094 power rail.
This procedure assumes you have prepared your panel, mounted your Bulletin
2094 power rail, and understand how to bond your system. For installation
instructions regarding equipment and accessories not included here, refer to the
instructions that came with those products.
Using the 2094 Mounting Brackets
You can use Bulletin 2094 mounting brackets to mount the power rail or LIM
module over the AC line filter. Refer to the 2094 Mounting Brackets Installation
Instructions, publication 2094-IN008
, when using mounting brackets with your
Kinetix 6000 drive system.
Topic Page
Introduction 47
Determine Mounting Order 48
Mount Modules on the Power Rail 49
SHOCK HAZARD: To avoid hazard of electrical shock, perform all
mounting and wiring of the Bulletin 2094 power rail and drive modules
prior to applying power. Once power is applied, connector terminals may
have voltage present even when not in use.
ATTENTION: Plan the installation of your system so that you can perform
all cutting, drilling, tapping, and welding with the system removed from
the enclosure. Because the system is of the open type construction, be
careful to keep any metal debris from falling into it. Metal debris or other
foreign matter can become lodged in the circuitry, which can result in
damage to components.