Rockwell Automation Publication 2094-UM001D-EN-P - May 2010 43
Planning the Kinetix 6000 Drive System Installation Chapter 2
Table 13 - Resistive Brake Module
Noise Reduction Guidelines for Drive Accessories
Refer to this section when mounting an AC (EMC) line filter or external shunt
module for guidelines designed to reduce system failures caused by excessive
electrical noise.
AC Line Filters
Observe these guidelines when mounting your AC (EMC) line filter (refer to the
figure on page 40
for an example):
Mount the AC line filter on the same panel as the Kinetix 6000 drive and
as close to the power rail as possible.
Good HF bonding to the panel is critical. For painted panels, refer to the
examples on page 32
.
Segregate input and output wiring as far as possible.
Wire/Cable Connections
Zone Method
Very
Dirty
Dirty Clean
Ferrite
Sleeve
Shielded
Cable
Resistive brake module coil power TB3-6 and TB3-7 X
Resistive brake module I/O
TB1-1…TB1-5
and TB3-8
X
Resistive brake module
drive and motor power
TB1 and TB2 X X
230V power TB4 X
IMPORTANT
CE test certification applies only to AC line filter and single power rail.
Sharing a line filter with multiple power rails may perform satisfactorily,
but the user takes legal responsibility.