194 Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Appendix A Specifications and Dimensions
External Shunt Module
Specifications
Bulletin 1394 passive shunt modules wire to the 2094-BSP2 (power rail
mounted) shunt module.
Table 113 - Bulletin 1394 Passive Shunt Module Specifications
Bulletin 1336 active shunt modules wire directly to the DC bus.
Table 114 - Bulletin 1336 Chopper Shunt Module Specifications
Refer to the Common DC Bus Selection Guide, publication DRIVES-SG001,
for dimensions and catalog number information for the Bulletin 1336 active
shunt modules.
External Shunt
Module Cat. No.
Drive
Voltage
V AC
Resistor
Value
Ω
Peak
Power
kW
Peak
Current
A
Continuous
Power
W
Shipping
Weight
kg (lb)
Bussmann
Replacement Fuse
1394-SR9A
230
(1)
4
41.0 101.25
300 3.63 (8)
FNQ-R-20-R1
(1)
460 160.0 200 FWP50A14F
1394-SR9AF
230
(1)
4
41.0 101.25
900 3.63 (8)
FNQ-R-20-R1
(1)
460 160.0 200 FWP50A14F
1394-SR36A
230
(1)
4
41.0 101.25
1800 8.6 (19)
FNQ-R-20-R1
(1)
460 160.0 200 FWP50A14F
1394-SR36AF
230
(1)
4
41.0 101.25
3600 9.0 (20)
FNQ-R-25-R1
(1)
460 160.0 200 FWP50A14F
(1) Requires the use of an FNQ fuse with an adapter to allow the smaller body fuse to fit the larger FWP fuse holder.
External Shunt
Module Cat. No.
Drive
Voltage
V AC
Turn-on
Value
V
Peak Transistor
Current
A
Resistor
Value, min
(1)
Ω
Shipping
Weight
kg (lb)
Fuse Replacement
(Ferraz Shawmut)
1336-WA115
230 375
400 1.25 11.34 (25) A70Q
1336-WA070 200 2.3 4.08 (9) A70Q
1336-WA018 50 9.0 3.18 (7) A60Q
1336-WB110
460 750
400 2.5 11.34 (25) A70Q
1336-WB035 100 9.0 4.08 (9) A70Q
1336-WB009 25 37.0 3.18 (7) A60Q
(1) Customer-supplied component.