EasyManua.ls Logo

Rockwell Automation Allen-Bradley 2094-BM01-S - Write the New IDN Parameter Value

Rockwell Automation Allen-Bradley 2094-BM01-S
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010 257
Changing the Default IDN Parameter Values Appendix E
Write the New IDN Parameter Value
Follow these steps to write the new IDN parameter value.
1. Configure a Message Configuration (MSG) instruction to write the IDN
parameter value required for your application.
In this example, the Message Configuration (MSG) instruction is set to
write the additional bus capacitance of your leader IAM power module.
a. From the Message Type pull-down menu, choose SERCOS IDN Write.
b. From the Identification Number pull-down menus, choose P-0-99.
2. Click New Tag.
3. The New Tag dialog box opens.
4. Type the name of your Source tag.
In this example, the tag name is Write_Value.
5. Click OK.

Table of Contents

Related product manuals