Rockwell Automation Publication 2094-UM001D-EN-P - May 2010 165
Troubleshooting the Kinetix 6000 Drive System Chapter 7
Shunt Module Status Indicators
Each of the shunt module status indicators provide specific troubleshooting
information.
Table 88 - General Shunt Module Troubleshooting
Module Status Under These Conditions
Shunt
Fault is latched. Until fault condition is corrected and cleared.
Fault is cleared.
Using MASR, MAFR, MGSR instructions or the HIM (red stop
button).
Only after the DC bus is discharged (bus status indicator is
flashing).
Drive must be configured with 2094-BSP2 shunt module or Bulletin
1394 external shunt module.
IAM/AM
Disabled (for DC bus
regulation).
When the 2094-BSP2 shunt module is used on a 230V system.
When either 230V or 460V system is configured with a Bulletin
1394 external shunt module.
When configured in Common-bus Follower mode.
Enabled to discharge the
DC bus.
Drive (IAM or leader IAM module) three-phase power is removed.
Disabled from discharging
the DC bus.
When configured in Common-bus Follower mode.
IMPORTANT
Under some fault conditions, two reset commands may be required to
clear drive and shunt module faults.