Rockwell Automation Publication 2094-UM001D-EN-P - May 2010 209
Interconnect Diagrams Appendix B
Shunt Module Wiring Examples
Refer to External Shunt Module Specifications on page 194, for the Bulletin
1394 and Bulletin 1336 external shunt module catalog numbers available for the
Kinetix 6000 drive systems.
Figure 93
Shunt Module Wired for Internal Operation (default configuration)
Refer to the Kinetix 6000 Shunt Module Installation Instructions, publication
2094-IN004
, for additional installation information.
Figure 94
Shunt Module with External Passive Shunt
Refer to the External Shunt Module Installation Instructions, publication
2090-IN004
, for additional installation information.
2094-BSP2
Kinetix 6000
Shunt Module
External Shunt Resistor
(RC) Connector
External Thermal Switch
(TS) Connector
COL
INT
DC+
2
1
3
2
1
TS2
TS1
COL
DC+
2094-BSP2
Kinetix 6000
Shunt Module
Bulletin 1394
External Passive
Shunt Module
External Shunt Resistor
(RC) Connector
External Thermal Switch
(TS) Connector
Resistor
Thermal
Switch
Only passive shunts with a thermal switch are wired to the TS connector
on the Kinetix 6000 shunt module. If your external passive shunt does not
have a thermal switch, leave the jumper (default configuration) in place
on the TS connector.