EasyManua.ls Logo

Rockwell Automation Allen-Bradley 2094-BM01-S - Remove the Power Rail

Rockwell Automation Allen-Bradley 2094-BM01-S
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
176 Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Chapter 8 Removing and Replacing the Kinetix 6000 Drive Modules
7. Reapply power to the system.
8. Verify that the system is operating properly.
Remove the Power Rail
This procedure assumes you have removed all modules from the power rail.
Follow these steps to remove the power rail.
1. Disconnect the braided grounding strap from the grounding stud located
on the right side of the power rail.
2. Loosen the mounting bolts (removing the bolts is not necessary).
3. Lift the power rail up and off of the mounting bolts.
TIP
Because parameter settings reside in RSLogix 5000 software, you
do not need to perform any tuning or set-up procedures.
Braided Ground Strap
100 mm (3.9 in.)
Bonded Cabinet Ground
Power Rail
2094-PRx
Braided Ground Strap
100 mm (3.9 in.)
Bonded Cabinet Ground
Power Rail
2094-PRSx

Table of Contents

Related product manuals