188 Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Appendix A Specifications and Dimensions
Contactor Ratings
These tables list the recommended contactor ratings for IAM modules installed
without a LIM module.
Table 106 - Contactor Ratings for 230V Systems
Table 107 - Contactor Ratings for 460V Systems
Transformer Specifications for Control Power Input
IAM Module (230V)
Cat. No.
Contactor
2094-AC05-MP5-x
100-C23x10 (AC coil)
100-C23Zx10 (DC coil)
2094-AC05-M01-x
2094-AC09-M02-x
100-C37x10 (AC coil)
100-C37Zx10 (DC coil)
2094-AC16-M03-x
100-C72x10 (AC coil)
100-C72Zx10 (DC coil)
2094-AC32-M05-x
100-C85x10 (AC coil)
100-C85Zx10 (DC coil)
IAM Module (460V)
Cat. No.
Contactor
2094-BC01-MP5-x
100-C23x10 (AC coil)
100-C23Zx10 (DC coil)
2094-BC01-M01-x
2094-BC02-M02-x
100-C37x10 (AC coil)
100-C37Zx10 (DC coil)
2094-BC04-M03-x
100-C60x10 (AC coil)
100-C60Zx10 (DC coil)
2094-BC07-M05-x
100-C72x10 (AC coil)
100-C72Zx10 (DC coil)
Attribute Value (460V system)
Input volt-amperes 750VA
Input voltage 460V AC
Output voltage 120…240V AC