EasyManua.ls Logo

Rockwell Automation Allen-Bradley 2094-BM01-S - Page 204

Rockwell Automation Allen-Bradley 2094-BM01-S
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
204 Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Appendix B Interconnect Diagrams
This configuration does not include a LIM module. You must supply input
power components. The single-phase and three-phase line filters are wired
downstream of fusing and the M1 contactor.
Figure 89
IAM Module (without LIM module)
ATTENTION: Wiring the contactor enable (CED) relay is required. To
avoid injury or damage to the drive, wire the contactor enable relay into
your safety control string.
Refer to Contactor Enable Relay on page 66
, for more information.
DC-
DC+
L3
L2
L1
CTRL 2
CTRL 1
1
2
3
4
5
6
1
2
CONT EN-
CONT EN+
1
2
BR+
BR-
MBRK -
MBRK +
COM
PWR
DBRK -
DBRK +
W
V
U
BR+
BR-
4
3
2
1
6
5
4
3
2
1
Single-phase Input
95…264V AC RMS
Notes 1, 2
Isolation
Transformer *
Note 5
Three-phase Input
195…264V AC RMS
or 324…528V AC RMS
Notes 1, 2
Bonded Cabinet Ground Bus *
Control Power
(CPD) Connector
Power Rail
Ground Stud
DC Bus
and
Three-phase
Input (IPD)
Connector
Three-phase
AC Line Filter
Note 3
Input Fusing *
Input Fusing *
M1 *
Notes 8, 9
* Indicates User Supplied Component
2094-ACxx-Mxx-x or
2094-BCxx-Mxx-x
IAM Module
Chassis
Single-phase
AC Line Filter
Note 3
Note 4
STOP *
START *
CR1 *
CR1 *
CR1 *
M1 *
Contactor Enable
(CED) Connector
Note 14
Ground Jumper
Note 11
Refer to Attention statement (Note 13).
Notes 8, 14
24V AC/DC
or
120V AC
50/60 Hz
Motor Brake
Connections
Resistive Brake
Connections
User Supplied
24V DC
Motor/Resistive
Brake (BC) Connector
Three-phase
Motor Power
Connections
Note 16
Motor Power
(MP) Connector
Cable Shield
Clamp
Note 10
Refer to table on page 200
for note information.

Table of Contents