236 Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Appendix C Upgrading the Kinetix 6000 Drive Firmware
The Progress dialog box opens and
flashing begins.
The drive module seven-segment
status indicator changes from the fixed 2, 3, or 4 to F, which indicates that
flashing is in progress.
After the flash information is sent
to the drive, the drive resets and
performs diagnostic checking.
14. Wait for the Progress dialog box to
time out.
15. The Update Status dialog box opens and indicates success or failure as
described below.
16. Click OK.
Flashing Status If
Success
1. Update complete appears in a GREEN Status dialog box.
2. Go to step 16.
Failure
1. Update failure appears in a RED Status dialog box.
2. Refer to ControlFLASH Firmware Upgrade Kit Quick Start,
publication 1756-QS105, for troubleshooting information.