Note 1
Note 4
Note 1
Auxiliary 230V AC
Input (TB4) Connector
(2090-XB120-xx only)
Kinetix 6000
Axis Module
2094-AMxx-S or
2094-BMxx-S
(Axis_1)
Cable Shield
Clamp
2090-XXNRB-14F0P7
RBM to Drive Interface Cable
Note 2
Motor Connections
(TB2) Connector
Drive Connections
(TB1) Connector
I/O Connections
(TB3) Connector
Motor/Resistive
Brake (BC) Connector
Motor Power
(MP) Connector
Cable Shield
Clamp
Cable Shield
Clamp
Motor Power
Connections
Bulletin 2090
Resistive Brake Module
2090-XBxx-xx
(RBM_1)
Note 1
Note 3
* Indicates User Supplied Component
Refer to the wiring examples in
Appendix B for motor power
cable catalog numbers.
Note 2
ATTENTION: The National Electrical Code and
local electrical codes take precedence over the
values and methods provided. Implementation
of these codes is the responsibility of the
machine builder.
Note Information
1 Cable shield clamp must be used in order to meet CE
requirements. No external connection to ground required.
2 For motor cable specifications, refer to the Kinetix Motion
Control Selection Guide, publication GMC-SG001
.
3 The BRKTMP0 signal can be wired to a ControlLogix input as
overtemp warning in user program.
4 Firmware revision 1.071 or later is required to use the DBRK
outputs on the Kinetix 6000 IAM or AM module.
5 The safety relay time delay should be set beyond the time
required to stop and disable the axis when running at full speed.
6 Drive Enable Input Checking must be selected when configuring
Axis Properties in RSLogix 5000 software.