Rockwell Automation Publication 2094-UM001D-EN-P - May 2010 59
Kinetix 6000 Connector Data Chapter 4
Kinetix 6000 drives do not support Heidenhain EnDat high-resolution feedback;
however, you can use the 2090-K6CK-KENDAT feedback module to convert
Heidenhain EnDat high-resolution feedback to Stegmann Hiperface. Pin
numbers in the table below refer to pins in the feedback module.
Table 20 - Heidenhain EnDat
Figure 25 - Pin Orientation for 15-pin Motor Feedback (MF) Connector
IMPORTANT
Only 2094-xCxx-Mxx-S and 2094-xMxx-S drives with firmware revision
1.116 support the use of 2090-K6CK-KENDAT feedback modules for
EnDat to Hiperface conversion.
Pin Description Signal Pin Description Signal
1 Sine differential input+ SIN+ 8 Serial data clock signal - CLK-
2 Sine differential input- SIN- 9 Serial data differential signal+ DATA+
3 Cosine differential input+ COS+ 10 Serial data differential signal - DATA-
4 Cosine differential input- COS- 11
Motor thermal switch+
(1)
TS+
5 Encoder power (+5V) EPWR_5V 12
Motor thermal switch-
(2)
TS-
6 Common ECOM 13 Reserved
7 Serial data clock signal + CLK+
(1) Not applicable unless motor has integrated thermal protection.
(2) When used with Allen-Bradley motors and Bulletin 2090 cables, pin 12 is reserved.
IMPORTANT
Combined motor-power cable length for all axes on the same DC bus
must not exceed 240 m (787 ft) with 460V systems or 160 m (525 ft) with
230V systems. Drive-to-motor power cables must not exceed 90 m
(295.5 ft).
System performance was tested at these cable length specifications.
These limitations also apply when meeting CE requirements.
Pin 11
Pin 6
Pin 15
Pin 1
Pin 10
Pin 5
15-pin IAM/AM