EasyManua.ls Logo

Rockwell Automation Allen-Bradley 2094-BM01-S - Page 92

Rockwell Automation Allen-Bradley 2094-BM01-S
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
92 Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Chapter 5 Connecting the Kinetix 6000 Drive System
Table 49 - IAM/AM Power Wiring Requirements
Table 50 - Shunt Module Power Wiring Requirements
Kinetix 6000 Drive
Cat. No.
Description
Connects to Terminals Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
Pin Signal
2094-AC05-Mxx-x,
2094-AC09-M02-x,
2094-BC01-Mxx-x,
2094-BC02-M02-x,
2094-AMP5-x,
2094-AM01-x,
2094-AM02-x,
2094-BMP5-x,
2094-BM01-x,
2094-BM02-x
Motor power
MP-4
MP-3
MP-2
MP-1
Motor power
cable depends
on motor/drive
combination.
6…1.5
(10…16)
10 (0.38)
0.5…0.6
(4.4…5.3)
2094-AC16-M03-x,
2094-AC32-M05-x,
2094-BC04-M03-x,
2094-AM03-x,
2094-AM05-x,
2094-BM03-x
10…1.5
(8…16)
10 (0.38)
1.2…1.5
(10.6…13.2)
2094-BC07-M05-x,
2094-BM05-x
30…2.5
(3…14)
16 (0.63)
2.4…3.0
(21.6…26.5)
IAM or AM
(230 or 460V)
2094-xCxx-Mxx-x and
2094-xMxx-x
Brake power
BC-6
BC-5
BC-4
BC-3
BC-2
BC-1
MBRK-
MBRK+
COM
PWR
DBRK-
DBRK+
0.75 (18) 10 (0.38)
0.22…0.25
(1.9…2.2)
IAM or AM
(230 or 460V)
2094-xCxx-Mxx-S and
2094-xMxx-S
Safe-off
SO-1
SO-2
SO-3
SO-4
SO-5
SO-6
SO-7
SO-8
SO-9
N/A
N/A
FDBK2+
FDBK2-
FDBK1+
FDBK1-
SAFETY
ENABLE2+
SAFETY
ENABLE-
SAFETY
ENABLE1+
24V +
24V_COM
0.75 (18)
(stranded wire
with ferrule)
1.5 (16)
(solid wire)
7.0 (0.275) 0.235 (2.0)
W
V
U
Cat. No. Description
Connects to Terminals Recommended
Wire Size
mm
2
(AWG)
Torque Value
N•m (lb•in)
Pin Signal
2094-BSP2
Shunt module
(230/460V)
1394-SRxxxx
External passive
shunt module
RC-1 DC+
10 (8)
(1)
1.2…1.5
(10.6…13.2)
RC-2 INT
RC-3 COL
Thermal switch
TS-1 TS1
0.75 (18)
0.22…0.25
(1.9…2.2)
TS-2 TS2
(1) 105 °C (221 °F), 600V.

Table of Contents

Related product manuals