92 Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Chapter 5 Connecting the Kinetix 6000 Drive System
Table 49 - IAM/AM Power Wiring Requirements
Table 50 - Shunt Module Power Wiring Requirements
Kinetix 6000 Drive
Cat. No.
Description
Connects to Terminals Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
Pin Signal
2094-AC05-Mxx-x,
2094-AC09-M02-x,
2094-BC01-Mxx-x,
2094-BC02-M02-x,
2094-AMP5-x,
2094-AM01-x,
2094-AM02-x,
2094-BMP5-x,
2094-BM01-x,
2094-BM02-x
Motor power
MP-4
MP-3
MP-2
MP-1
Motor power
cable depends
on motor/drive
combination.
6…1.5
(10…16)
10 (0.38)
0.5…0.6
(4.4…5.3)
2094-AC16-M03-x,
2094-AC32-M05-x,
2094-BC04-M03-x,
2094-AM03-x,
2094-AM05-x,
2094-BM03-x
10…1.5
(8…16)
10 (0.38)
1.2…1.5
(10.6…13.2)
2094-BC07-M05-x,
2094-BM05-x
30…2.5
(3…14)
16 (0.63)
2.4…3.0
(21.6…26.5)
IAM or AM
(230 or 460V)
2094-xCxx-Mxx-x and
2094-xMxx-x
Brake power
BC-6
BC-5
BC-4
BC-3
BC-2
BC-1
MBRK-
MBRK+
COM
PWR
DBRK-
DBRK+
0.75 (18) 10 (0.38)
0.22…0.25
(1.9…2.2)
IAM or AM
(230 or 460V)
2094-xCxx-Mxx-S and
2094-xMxx-S
Safe-off
SO-1
SO-2
SO-3
SO-4
SO-5
SO-6
SO-7
SO-8
SO-9
N/A
N/A
FDBK2+
FDBK2-
FDBK1+
FDBK1-
SAFETY
ENABLE2+
SAFETY
ENABLE-
SAFETY
ENABLE1+
24V +
24V_COM
0.75 (18)
(stranded wire
with ferrule)
1.5 (16)
(solid wire)
7.0 (0.275) 0.235 (2.0)
Cat. No. Description
Connects to Terminals Recommended
Wire Size
mm
2
(AWG)
Torque Value
N•m (lb•in)
Pin Signal
2094-BSP2
Shunt module
(230/460V)
1394-SRxxxx
External passive
shunt module
RC-1 DC+
10 (8)
(1)
1.2…1.5
(10.6…13.2)
RC-2 INT
RC-3 COL
Thermal switch
TS-1 TS1
0.75 (18)
0.22…0.25
(1.9…2.2)
TS-2 TS2
(1) 105 °C (221 °F), 600V.