Do you have a question about the Rockwell Automation Allen-Bradley GuardShield 450L-B4FNxYD and is the answer not in the manual?
Brand | Rockwell Automation |
---|---|
Model | Allen-Bradley GuardShield 450L-B4FNxYD |
Category | Safety Equipment |
Language | English |
Identifies the target audience for the manual.
Lists modifications and updates made in this manual version.
Defines abbreviations and technical terms used in the manual.
Lists related Rockwell Automation publications for further information.
Provides an overview of the 450L GuardShield safety light curtain family and its features.
Lists the items included in a complete GuardShield safety light curtain system package.
Details the firmware versions and their associated features for 450L components.
Outlines the safety standards and directives the 450L safety light curtain complies with.
Provides functional safety data and PFH values for 450L safety light curtain applications.
Confirms the safety certifications and compliance of the 450L safety light curtains.
Specifies the regulations and standards that must be followed for proper installation.
Describes applications and environmental conditions that should be avoided to prevent misuse.
Explains the fundamental working principle of the 450L safety light curtain system.
Describes the integrated laser alignment system (ILAS) for 450L-E safety light curtains.
Details the four configurable start modes available for GuardShield safety light curtains.
Explains how to perform a power cycle to reset the system after a lockout condition.
Describes the EDM feature for monitoring external control contactors and safety devices.
Explains the low operating range feature to minimize interference from neighboring optical sensors.
Details the beam coding feature to prevent optical crosstalk between adjacent safety light curtains.
Introduces blanking and reduced resolution features for allowing objects to pass through the protective field.
Explains how to configure fixed blanking by teaching specific objects to be ignored.
Covers the muting functionality, its types, and activation requirements.
Describes the MDO function to temporarily reactivate OSSD outputs after a muting error.
Details the two-sensor T-type muting arrangement and its operation.
Explains the two-sensor L-type muting with an additional enable signal for specific timing control.
Describes the four-sensor muting configuration for irregular pallet loads or smaller pallets.
Explains how to cascade multiple 450L-E safety light curtains for extended coverage.
Details how blanking features are applied in cascading configurations.
Discusses the factors affecting the light curtain's response time.
Provides standard response times for basic ON/OFF applications.
Details response times when advanced features like blanking and beam coding are used.
Explains the additional response time adder due to cascading plug-ins.
Describes how CCW software calculates response times for cascaded systems.
Details how to set the DIP switches on receiver plug-ins for desired functionality.
Lists the function and default settings for the 450L-APR-ON-5 connection plug-in.
Lists the function and default settings for the 450L-APR-ED-8 connection plug-in.
Lists the function and default settings for the 450L-APR-BL-5 connection plug-in.
Lists the function and default settings for the 450L-APR-MU-8 connection plug-in.
Lists the function and default settings for the 450L-APR-UN-8 universal plug-in.
Describes the procedure to confirm a new system configuration after changes.
Explains the importance and factors for determining the required safety distance.
Provides the U.S. safety distance calculation formula.
Details the OSHA safety distance formula for minimum safety requirements.
Presents the ANSI safety distance formula, recommended for USA applications.
Outlines the European safety distance calculation formula based on EN ISO standards.
Specifies the minimum distance required from reflective surfaces to prevent detection issues.
Discusses the use of corner mirrors with safety light curtains and installation considerations.
Guides on the preparation, selection, and installation of the GuardShield safety light curtain system.
Illustrates the correct method for aligning transmitter and receiver sticks.
Provides illustrations and guidelines for correct safety light curtain installation to ensure safety.
Shows examples of incorrect installation practices that compromise safety.
Addresses potential issues and measures for mounting multiple light curtains closely.
Details methods to prevent optical interference and crosstalk between adjacent light curtains.
Describes the available mounting bracket kits for installing the safety light curtains.
Provides details on the standard top/bottom mounting kit supplied with each stick.
Explains the side mounting bracket for alternative installation orientations.
Describes shock mount brackets for applications with high shock and vibration.
Details the replacement mounting kit for easier conversion from existing installations.
Covers the necessary precautions and steps for electrical installation of the system.
Explains the process of selecting and installing transmitter, receiver, or universal plug-ins.
Guides on how to properly install plug-ins to maintain IP65 rating.
Provides pin assignments and details for transmitter plug-ins.
Provides pin assignments and details for receiver plug-ins.
Explains the pin assignments for cascading plug-ins used in transmitter and receiver configurations.
Details the connection cable requirements for transmitter plug-ins.
Details the connection cable requirements for receiver plug-ins.
Specifies the requirements for the external voltage supply (24V DC) for the light curtain.
Explains the recommended grounding types (Protective Earth and Functional Earth) for the light curtains.
Describes how to connect the EDM feature to monitor external contactors.
Explains the function and operation of the restart button.
Details the OSSD output signal processing and connection requirements.
Specifies the times required for OSSD restart after protective field clearance.
Explains the use of test pulses for checking OSSD output faults.
Provides typical wiring diagrams for connecting the light curtain to external contactors.
Illustrates direct connection to external contactors for safety output control.
Shows an example connection to a Guardmaster SI Safety Relay.
Explains the use of a T-connector for system design and connection.
Demonstrates connecting to a GuardLink tap using a splitter.
Shows an example connection to a 1732 ArmorBlock module.
Explains how to interpret the status indicators on the light curtain sticks.
Describes the different status indicator lights and their meanings based on stick type.
Lists the normal operation status indicators, their colors, and behaviors.
Details the operation and functions of the optical push button.
Provides guidance on troubleshooting system errors based on status indicators.
Explains how to interpret error codes shown by the STS status indicator.
Lists common errors, lockouts, and their corresponding corrective actions.
Describes the OID for visualizing protective field status and diagnostics.
Guides on using CCW software for diagnosing and troubleshooting the light curtain.
Provides instructions and precautions for maintaining the safety light curtain system.
Outlines the regular inspection actions and their frequency for ensuring safe operation.
Instructions for cleaning the optic front window to maintain system reliability.
Provides guidance on the proper disposal of unserviceable devices.
Explains the information found on product labels and packaging.
Details the explanation and meaning of information on stick labels.
Explains the information and principle indicated on plug-in labels.
Introduces the Connected Components Workbench software for monitoring and configuring 450L light curtains.
Explains the concept of multiple subconfigurations for advanced setups.
Guides on how to create a new project within the CCW software.
Describes the different sections and layout of the CCW workbench interface.
Explains the Project Organizer for managing devices within a project.
Details the general setup and customization options for a project device.
Guides on selecting appropriate hardware settings for the light curtain.
Explains the function of DIP switches on the connection plug-in for configuration.
Shows how to check the status of the USB connection to the light curtain.
Details the setup and key elements of subconfigurations, especially when using OID.
Outlines the default general settings applicable to muting and blanking functions.
Introduces the General Purpose Input Output (GPIO) window for configuring inputs and outputs.
Guides on selecting and configuring GPIO settings for muting sensors and other inputs/outputs.
Explains how to use the Diagnose window for troubleshooting and viewing status.
Describes how to export light curtain setup and diagnostic data to a CSV file.
Details the reset procedure for clearing lockouts and powering the light curtain off/on.
Explains the process of locking configurations before run mode.
Describes the mode symbols used to indicate the operating status of the light curtain.
Outlines the conditions and steps for enabling the Teach function.
Explains how to turn the integrated laser alignment ON and OFF.
Describes how to view the status of individual beams and intensity levels.
Provides an example wiring diagram for two-sensor muting configurations.
Guides on configuring hardware settings, specifically for muting setup.
Details how to select and adjust muting types and time parameters.
Introduces the blanking features and lens identification for configuration.
Explains how to identify lenses for finger and hand resolution for blanking setup.
Describes how to define zones for blanking, floating, or reduced resolution.
Lists the types of blanking configurations available.
Explains the concept and rules for fixed blanking zones.
Guides on learning new arrangements of fixed blanking using the software.
Details the steps for connecting to the light curtain and configuring blanking.
Explains the floating blanking feature, allowing object movement within a lens range.
Details the settings for floating blanking configuration.
Outlines the rules enforced by CCW software for floating blanking.
Explains how to calculate minimum and maximum object heights for OSSD outputs to remain ON.
Describes reduced resolution blanking, where objects don't need to be in the zone.
Provides rules for reduced resolution blanking based on object size and lens values.
Details the three steps required to change a configuration in the light curtain.
Guides on the initial steps to configure the light curtain offline.
Explains how to upload the project from the light curtain back to the CCW software.
Describes how to lock the configuration to confirm it.
Guides on connecting the CCW software to the light curtain device.
Explains how CCW software synchronizes hardware changes before downloading new configurations.
Details how to share projects and devices using export/import routines.
Guides on exporting a project to a CCW software archive file.
Explains the default directory and filename conventions for exporting projects.
Describes the confirmation message shown after exporting a project.
Explains how to select the correct archive filename for import.
Guides on importing a project from a CCW software archive file.
Describes exporting a single device configuration to a 7-Zip file.
Guides on importing a device configuration from a zip file.
Details the process of updating firmware for the light curtain and OID.
Lists the safety ratings and standards compliance for the 450L safety light curtains.
Provides key operating characteristics such as protective field length, resolution, and operating range.
Details the response times for 450L-B and 450L-E light curtains under various conditions.
Lists the attributes for receiver, cascading, and universal plug-ins.
Specifies the safety output characteristics of the receiver plug-in.
Describes the characteristics of the status outputs available on the receiver plug-in.
Covers operating temperature, humidity, enclosure rating, and vibration resistance.
Details electrical protection features like short circuit and overload protection.
Provides material specifications, dimensions, torque values, and accessory information.
Lists the certifications and compliance standards for the product.
Declares conformity with relevant EU directives and standards.
Shows the physical dimensions of the safety light curtain transceiver sticks.
Guides on selecting the appropriate 450L light curtain model based on specifications.
Details the catalog numbers and specifications for different 450L transceiver sticks.
Lists the types of plug-ins available and their functions.
Lists optional accessories for mounting, alignment, and other functions.
Describes mounting brackets for corner mirrors and transceiver sticks.
Details the purpose and specifications of polycarbonate weld shields.
Illustrates vertical mounting for point of operation and access control applications.
Shows horizontal mounting for hazardous zone safe guarding applications.
Provides an example application for fixed teach-in blanking, like on a punch press.
Illustrates an example setup for cascading safety light curtain segments.