Remote Commands in the Receiver Application
R&S
®
ESW
545User Manual 1177.6298.02 ─ 08
Example:
CALC:THR -82DBM
Sets the threshold value to -82 dBm.
Manual operation: See "Search Threshold" on page 236
CALCulate<n>:THReshold:STATe <State>
This command turns a threshold for the marker peak search on and off (for all markers
in all windows).
Suffix:
<n>
.
irrelevant
Parameters:
<State> ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
CALC:THR:STAT ON
Switches on the threshold line.
Manual operation: See "Deactivating All Search Limits" on page 236
15.7.4.4 Marker Positioning
Markers................................................................................................................. 545
Delta Markers........................................................................................................548
Markers
CALCulate<n>:MARKer<m>:MAXimum:LEFT...................................................................545
CALCulate<n>:MARKer<m>:MAXimum:NEXT..................................................................546
CALCulate<n>:MARKer<m>:MAXimum[:PEAK]................................................................ 546
CALCulate<n>:MARKer<m>:MAXimum:RIGHt..................................................................546
CALCulate<n>:MARKer<m>:MINimum:LEFT....................................................................546
CALCulate<n>:MARKer<m>:MINimum:NEXT................................................................... 547
CALCulate<n>:MARKer<m>:MINimum[:PEAK]................................................................. 547
CALCulate<n>:MARKer<m>:MINimum:RIGHt...................................................................547
CALCulate<n>:MARKer<m>:MAXimum:LEFT
This command moves a marker to the next lower peak.
The search includes only measurement values to the left of the current marker posi-
tion.
In the spectrogram, the command moves a marker horizontally to the maximum level in
the currently selected frame. The vertical marker position remains the same.