EasyManua.ls Logo

Rohde & Schwarz SMAB-B92 - Page 183

Rohde & Schwarz SMAB-B92
778 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List and Sweep Mode
R&S
®
SMA100B
181User Manual 1178.3834.02 ─ 05
You can define up to 10 markers, and assign one of them to the output at a time.
When the sweep run has reached the marker frequency, the R&S SMA100B acti-
vates the marker signal and supplis it at the Marker User1 connector. The duration
of the active signal corresponds to the dwell time of a step.
Settings
Frequency x ............................................................................................................... 181
State ...........................................................................................................................181
Marker Polarity............................................................................................................182
Active Marker ............................................................................................................. 182
Frequency x
Sets the frequency that the selected marker indicates.
When the specified value is used, the polarity of the marker signal changes, as
selected with the parameter .
Remote command:
[:SOURce<hw>]:SWEep[:FREQuency]:MARKer<ch>:FREQuency on page 652
State
Enables the selected marker.
A marker signal at the output connector marks the moment the specified frequency val-
ues is used.
Remote command:
[:SOURce<hw>]:SWEep[:FREQuency]:MARKer<ch>:FSTate on page 653
Sweep Mode Settings

Table of Contents