Remote Control Commands
R&S
®
SMA100B
532User Manual 1178.3834.02 ─ 05
Parameters:
<Delay> float
*RST: 1ms
Example: See Example "Perform pulse modulation" on page 529.
Manual operation: See "Pulse Delay" on page 89
[:SOURce<hw>]:PULM:DOUBle:DELay <Delay>
Sets the delay from the start of the first pulse to the start of the second pulse.
Parameters:
<Delay> float
*RST: 1E-6
Example: See Example "Perform pulse modulation" on page 529.
Manual operation: See "Double Pulse Delay" on page 89
[:SOURce<hw>]:PULM:DOUBle:WIDTh <Width>
Sets the width of the second pulse.
Parameters:
<Width> float
Increment: 5E-9
Example: See Example "Perform pulse modulation" on page 529.
Manual operation: See "Double Pulse Width" on page 89
[:SOURce<hw>]:PULM:DOUBle:STATe <State>
Provided for backward compatibility with former Rohde & Schwarz signal generators.
Works like the command [:SOURce<hw>]:PULM:MODE DOUBle.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
[:SOURce<hw>]:PULM:STATe <State>
Activates pulse modulation.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Perform pulse modulation" on page 529.
Manual operation: See "State" on page 76
SOURce Subsystem