Remote Control Commands
R&S
®
SMA100B
558User Manual 1178.3834.02 ─ 05
Manual operation: See "Down Frequency" on page 131
[:SOURce<hw>]:ILS[:GS|GSLope]:MODE <Mode>
Sets the operating mode for the ILS glide slope modulation signal.
Parameters:
<Mode> NORM | ULOBe | LLOBe
NORM
ILS glide slope modulation is active.
ULOBe
Amplitude modulation of the output signal with the upper lobe
(90Hz) signal component of the ILS glide slope signal is active.
LLOBe
Amplitude modulation of the output signal with the lower lobe
(150Hz) signal component of the ILS glide slope signal is active.
*RST: NORM
Example: See Example "Configure and generate an ILS glide slope signal"
on page 542.
Manual operation: See "Operating Mode" on page 130
[:SOURce<hw>]:ILS[:GS|GSLope]:PHASe <Phase>
Sets the phase between the modulation signals of the upper and lower antenna lobe of
the ILS glide slope signal.
Zero crossing of the lower lobe (150Hz) signal serves as a reference. The angle refers
to the period of the signal of the right antenna lobe.
Parameters:
<Phase> float
Range: -60 to 120
Increment: 0.01
*RST: 0.0
Example: See Example "Configure and generate an ILS glide slope signal"
on page 542.
Manual operation: See "Up/Down Phase" on page 131
[:SOURce<hw>]:ILS:GS|GSLope:PRESet
Sets the parameters of the ILS glide slope component to their default values (*RST
values specified for the commands).
For other ILS preset commands, see [:SOURce<hw>]:ILS:PRESet on page 546.
Example:
SOURce1:ILS:GS:PRESet
Usage: Event
SOURce Subsystem