8.9.8 Enable propose field
Overview
Figure 65: Enable propose field
1
Proposal for a protective field
You can have a protective field or warning field suggested by Safety Designer.
F
or this purpose, the safety laser scanner scans the visible surrounding contour several
times. Based on the data obtained, the Safety Designer suggests the contour and size
of the field.
You can create a field using the Pr
opose field tool.
Important information
NOTE
If y
ou propose a protective field, the proposal does not replace the calculation of the
minimum distance. You must calculate the minimum distance and check whether the
size of the proposed protective field is sufficient. You must also take into account the
measurement tolerances of the safety laser scanner