Page #27 background image
Figure 17: Prevent stepping over
Further topics
•
"Mount
ing", page 65
5.3.1 Protection from influences
A safety laser scanner can be influenced by the beams from a different laser source
in c
lose proximity to it, e.g. by another laser scanner. This may impair the machine’s
availability. That is to say, the affected safety laser scanner switches the machine off,
although no people are situated in the protective field.
A safety laser scanner may be dazzled by a strong external light source in the scan
plane. This may impair the machine’s availability. That is to say, the safety laser scanner
switches the machine off, although no people are located in the protective field.
You can use the following measures to increase the availability:
•
The safety laser scanner has a function for interference protection. The scan cycle
time is adjusted in small increments. You can increase the availability by choosing
different modes for interference protection in adjacent safety laser scanners, see
"Additional interference protection", page 88.
•
Higher multiple sampling reduces the likelihood of a laser source influencing the
safety laser scanner. You can increase the availability by setting multiple sampling
to the highest value permitted in your application, while taking minimum distances
into account, see "Multiple sampling", page 87.
•
You can further increase the availability by choosing a suitable mounting method,
see "Mounting methods for protection from interference from systems in close
proximity", page 160.
•
Avoid external light sources in the scan plane. Mount the safety laser scanner
so that it cannot be dazzled by incoming sunlight. Do not position halogen lights,
infrared light sources or stroboscopes directly on the scan plane.
You can check the beam path of the safety laser scanner with the LS-80L scan finder
(part no. 6020756).
NOTE
Y
ou must comply with the standard ISO 13855 when choosing the mounting method.
PROJECT PLANNING 5
8025870/2020-09-04 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O
27
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Core I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Core I/O and is the answer not in the manual?

SICK microScan3 Core I/O Specifications

General IconGeneral
BrandSICK
ModelmicroScan3 Core I/O
CategoryScanner
LanguageEnglish

Related product manuals