microScan3 Core – PROFINET microScan3 Pro – PROFINET
Devices with a max. protec‐
t
ive field range of 9.0 m
100 mm
Additional supplement
Z
R
for reflection-based meas‐
urement errors
350 mm
Deviation from ideal flatness
of sc
an field at 5.5 m
2)
≤ ± 100 mm ≤ ± 100 mm
Deviation from ideal flatness
of scan field at 9.0 m
3)
≤ ± 100 mm
Distance of mirror rotational
a
xis (zero point of x and y
axis) to rear side of device
56 mm
Distance between center
point of scan plane and top
edge of the housing
40 mm
Multiple sampling 2 … 16
4)
2 to 16
4)
1)
Protective field resolution 60 mm only available for devices with max. protective field range of 9.0 m.
2)
Devices with a max. protective field range of 4.0 m and devices with max. protective field range of 5.5 m.
3)
Devices with a max. protective field range of 9.0 m
4)
Can be adjusted collectively for all fields or individually for each field.
Safety-related parameters
Table 39: Safety-related parameters
microScan3 Core – PROFINET microScan3 Pro – PROFINET
Type Type 3 (IEC 61496)
Safety integrity level SIL 2 (IEC 61508)
SIL claim limit SILCL 2 (IEC 62061)
Category Category 3 (ISO 13849-1) Category 3 (ISO 13849-1)
Performance level PL d (ISO 13849-1)
PFH
D
(me
an probability of a
dangerous failure per hour)
8 × 10
–8
T
M
(mis
sion time) 20 years (ISO 13849-1) 20 years (ISO 13849-1)
Safe status when a fault
oc
curs
The safety outputs via the network are logic 0.
Interfaces
T
able 40: Interfaces
microScan3 Core – PROFINET microScan3 Pro – PROFINET
Safety outputs via network
Quantity
Devices with a max. protec‐
t
ive field range of 4.0 m
4 8
Devices with a max. protec‐
tive field range of 5.5 m
4 8
Devices with a max. protec‐
t
ive field range of 9.0 m
4
Duration of OFF state ≥ 80 ms
Automated restart after 2 s … 60 s (can be configured) 2 s to 60 s (can be configured)
Voltage supply
TECHNICAL DATA 13
8021219/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET
167