EasyManua.ls Logo

SICK microScan3 - Page 168

SICK microScan3
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
microScan3 Core – PROFINET microScan3 Pro – PROFINET
Connection type
Devices with RJ45 connec‐
t
ion
M12 male connector, 5-pin, L-
coded
M12 male connector 5-pin, L-
coded
Devices with SCRJ connec‐
tion
M12 male connector, 5-pin, L-
coded
M12 male connector 5-pin, L-
coded
Devices with M12 connec‐
t
ion
M12 male connector, 4-pin, A-coded
Length of cable (power supply unit tolerance ± 5%)
Length of cable with wire
cross-section 1.5 mm²
≤ 100 m
Configuration and diagnostic interface
Type of interface USB 2.0
Connection type USB 2.0 mini-B (female connector)
Transmission rate ≤ 12 Mbit/s
Length of cable ≤ 5 m
Fieldbus/industrial network
Type of fieldbus integration PROFINET PROFIsafe
Connection type
Devices with RJ45 connec‐
t
ion
RJ45 female connector, for push-pull male connector (copper)
Devices with SCRJ connec‐
tion
SCRJ female connector, for push-pull male connector (fiber-
optic cables)
Devices with M12 connec‐
tion
M12 female connector, 4-pin, D-coded
Supported protocol versions
P
ROFINET specification V2.3
PROFIsafe profile in accordance with specification V2.4
PROFIsafe profile in accordance with specification V2.6.1
GSDML Acc. to GSDML specification V2.33
Cycle time 1 ms, 2 ms, 4 ms, 8 ms, 16 ms …
Conformance Conformance Class C
Network management
SNMP
MIB-2
LLDP in ac
cordance with IEEE 802.1AB
MRP client support
Net load Net load class III in acc. with security level 1 test
Switch properties
2 port real-time switch compliant with IEEE 802
Conformance Class C
Port properties
100BASE-TX (only devices with M12 or RJ45 connection)
Auto negotiation (only devices with M12 or RJ45 connec‐
tion)
Auto crossover (MDIX) (only devices with M12 or RJ45 con‐
nection)
Auto polarity (only devices with M12 or RJ45 connection)
100BASE-POF (only devices with SCRJ connection)
Diagnostics
I&M d
ata sets 0 … 5
PROFINET alarms
Attenuation diagnostics with POF (only devices with SCRJ
connection)
13 TECHNICAL DATA
168
O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET 8021219/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3