Name Use Data type Definition Values Safety implica‐
t
ion
SetMonitoringCaseNoTable1 Safety function USINT Monitoring case num‐
ber (Monitoring case
table 1)
Activates the monitor‐
ing case with the cor‐
responding number in
monitoring case table
1.
0 = invalid Safety-relevant
parameter
1 … 254 = num‐
ber of t
he moni‐
toring case
SetMonitoringCaseNoTable2 Safety function USINT Monitoring case num‐
ber (Monit
oring case
table 2)
Activates the monitor‐
ing case with the cor‐
responding number in
monitoring case table
2.
0 = invalid Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
SetMonitoringCaseNoTable3 Safety function USINT Monitoring case num‐
ber (Monit
oring case
table 3)
Activates the monitor‐
ing case with the cor‐
responding number in
monitoring case table
3.
0 = invalid Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
SetMonitoringCaseNoTable4 Safety function USINT Monitoring case num‐
ber (Monit
oring case
table 4)
Activates the monitor‐
ing case with the cor‐
responding number in
monitoring case table
4.
0 = invalid Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
StopAlarmDetection Additional func‐
t
ion
BOOL Stop Event history 0 = event history
active, field inter‐
ruptions are
recorded
Parameter with‐
out safety impli‐
cation
1 = event history
not active, field
interruptions are
not recorded,
existing record‐
ings are retained
TriggerDeviceRebootWithNet‐
work
Additional func‐
tion
BOOL Restart device com‐
pletely
Restarts the device and
the network stack. The
internal switch function
is interrupted.
0 = no restart Parameter with
implication for
the safety func‐
tion
0-1-0 = device
r
estart
(duration of sta‐
tus 1 ≥ 120 ms)
1 = ignored
TriggerDeviceRebootWithout‐
N
etwork
Additional func‐
tion
BOOL Restarting safety func‐
tion and connections
Restarts the device
without ending the net‐
work stack. The internal
switch function is not
interrupted.
0 = no restart Parameter with
implication for
the safety func‐
tion
0-1-0 = device
restart
(duration of sta‐
tus 1 ≥ 120 ms)
1 = ignored
13 TECHNICAL DATA
178
O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET 8021219/1ELL/2022-01-21 | SICK