What happens when tamper protection activates on SICK microScan3?
C
chase18Sep 16, 2025
If your SICK Scanner's tamper protection is activated because it's not detecting a contour within the set tolerance band, all safety outputs will be in the OFF state.
T
Tracey Fletcher MDSep 18, 2025
What happens if SICK microScan3 measures no values within the distance measurement range?
K
kristajohnstonSep 18, 2025
If your SICK Scanner's tamper protection is activated because it measures no values within the distance measurement range in an area of at least 90°, all safety outputs will be in the OFF state.
D
Daniel PorterSep 18, 2025
How to troubleshoot no supply voltage and no Ethernet connection on SICK Security Sensors?
M
Madison LewisSep 18, 2025
If your SICK Security Sensors have no supply voltage and no Ethernet connection, check the voltage supply, the network cable, and whether the device at the other end of the network cable is switched on.
J
Jeanette KelleySep 18, 2025
What to do if SICK Security Sensors have incompatible configuration?
C
ckerrSep 22, 2025
If the configuration in the system plug does not match the device’s functionality, check the device variant. You may also need to replace or reconfigure the device.
S
Sarah ClarkeSep 23, 2025
How to resolve incompatible firmware issues with SICK Security Sensors?
K
Kerry HeathSep 23, 2025
To resolve incompatible firmware issues, check the firmware version of the device. If the configuration in the system plug does not match the device’s firmware version, replace or reconfigure the device.
C
carpentercaitlinSep 23, 2025
Why am I getting a temperature error on my SICK Security Sensors?
J
Jason PattersonSep 23, 2025
If the safety laser scanner’s operating temperature has exceeded or fallen below the permitted range, check whether the safety laser scanner is being operated in accordance with the permissible ambient conditions.
D
Debbie JohnsonSep 23, 2025
What to do if SICK Security Sensors show correctable error (e.g. CIP connection interrupted)?
J
Joshua LeeSep 23, 2025
If there is a correctable error such as a CIP connection interruption, reestablish the CIP connection.
M
Mrs. Brianna HallAug 31, 2025
What to do if my SICK Scanner has OSSD short-circuit to 24 V?
A
Anita CooperAug 31, 2025
If there is a short-circuit to 24 V at an OSSD, check the wiring.
J
Jacob JenkinsAug 25, 2025
How to resolve a 'Fault in the reset input' on my SICK Scanner?
L
Laura CervantesAug 25, 2025
If an invalid signal is applied at a reset input because the reset button has been pressed for too long, too frequently, or is defective, check whether the reset pulse fulfills the requirements.
G
George HunterAug 25, 2025
Why is my SICK microScan3 Scanner showing an incompatible configuration and what should I do?
N
Nicholas ShawAug 26, 2025
If the configuration in the system plug does not match the device’s functionality, check the device variant. You may need to replace or reconfigure the device.