What to do if my SICK microScan3 shows a fault in the system plug?
W
wellsbenjaminSep 4, 2025
If the system plug has an internal fault, try restarting the device using the display or Safety Designer, or interrupt the power supply for at least 2 seconds. If this does not fix the fault, replace the system plug.
C
Christine BrooksSep 4, 2025
What to do if my SICK microScan3 Scanner has an incompatible system plug?
R
Rachel SalinasSep 4, 2025
If the system plug is unsuitable for the safety laser scanner, check the part number or the type code and replace the system plug.
K
Kevin BookerSep 5, 2025
What should I do if my SICK microScan3 Scanner shows a fault in the external device monitoring (EDM)?
L
lisa73Sep 5, 2025
If a faulty signal is applied at the external device monitoring (EDM) because the allowed tolerance time has been exceeded, check whether the connectors are wired correctly and operating correctly.
A
Adrian JonesSep 6, 2025
What causes a SICK Scanner to display 'Defective sequence of monitoring cases' and how can I resolve it?
J
Jody LeeSep 6, 2025
If the current input conditions do not match the configured sequence of monitoring cases, use Safety Designer to check the configuration and check the machine’s work process.