EasyManua.ls Logo

SICK MLG-2 Pro

SICK MLG-2 Pro
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTE
When two MLG-2s are placed opposite one another and their light beams are in oppo‐
site directions,1 reflections may occur from sender 1 to receiver 2 in the case of shiny
objects.
4.2.2 Mounting with light in the same direction
When several MLG-2s are mounted with their light beams oriented in the same direc‐
tion, a minimum distance must be maintained between the MLG-2s. The minimum dis‐
tance increases as the distance between the sender and receiver increases and is
dependent on the operating range.
Figure 27: Distances when light is in the same direction
X Operating range
Y Minimum distance of the MLG-2
Z Minimum distance of the MLG-2
4 MOUNTING
36
O P E R A T I N G I N S T R U C T I O N S | MLG-2 Pro 8017460.ZIK1/2017-02-13 | SICK
Subject to change without notice

Table of Contents

Related product manuals