Output settings
For general options for analog outputs, see section see "Advanced settings for the out‐
puts", page 84.
7.5.3 Object detection
An analog output changes its output current analogously to the total number of beams
blocked.
Figure 91: Object detection
The output current increases with the number of beams blocked.
Output settings
General options for analog outputs see "Advanced settings for the outputs", page 84.
7.5.4 Measuring the outer or inner dimension
An analog output changes its output current analogously to the outer or inner dimen‐
sion of an object.
The output displays the outer or inner dimension of an object. On this basis, the output
provides a current analogous to the number of blocked/made beams.
Figure 92: Measurement of the outside dimen‐
sion
Figure 93: Measurement of the inside dimen‐
sion
b
Configure whether you want to measure the outside dimension or inside dimen‐
sion.
7
CONFIGURATION WITH SOPAS ET
82
O P E R A T I N G I N S T R U C T I O N S | MLG-2 Pro 8017460.ZIK1/2017-02-13 | SICK
Subject to change without notice