Figure 112: Performance options for Transparent operating mode
You can change the response time, operating reserve, or minimum detectable absorp‐
tion by moving the slider up or down.
NOTE
•
The configurable performance options depend on the operating mode selected.
•
The performance options are dependent on each other.
•
A teach-in process must be performed after most changes. A button is provided in
the performance options for this purpose.
b
Click the button to perform the teach-in process and to apply the modified per‐
formance options.
✓
The system boundaries resulting from the performance options are displayed on
the left in SOPAS ET (see "System boundaries, status, and interfaces", page 55).
Response time
The response time depends on the scan method and the beam function. A short
response time requires a high-speed scan and the parallel-beam function.
b
Select one of the following options:
•
Fast – High-speed scan and parallel-beam function are active
•
Medium – High-speed scan not active and parallel-beam function active
7 CONFIGURATION WITH SOPAS ET
94
O P E R A T I N G I N S T R U C T I O N S | MLG-2 Pro 8017460.ZIK1/2017-02-13 | SICK