7.1.4 Safely remove the memory card
NOTICE
Data loss from improper handling of the memory card
If you remove the memory card when the converter is switched on without implementing the
"safe removal" function you may destroy the file system on the memory card. The data on
the memory card are lost. The memory card will only function again after formatting.
Only remove the memory card using the "safe removal" function.
Procedure with STARTER
To safely remove the memory card, proceed as follows:
1. Go online.
2. In the Drive Navigatorselect the following screen form:
3. Click on the button to safely remove the memory card.
STARTER will tell you whether you can remove the memory card from the inverter.
You have now safely removed the memory card from the inverter.
Saving the settings and series commissioning
7.1 Backing up and transferring settings using a memory card
Converter with the CU230P-2 Control Units
378 Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257946B AE