Service Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
12-70 HiPath 3000/5000 V9, Service documentation
service.fm
Guided Maintenance
12-025 watchdog timer
interrupt
HiPath 3800, Off-
set 0x1020,
Watchdog Timer
Interrupt
Create a trace.
Create a stack dump.
Save a snapshot.
12-026 Data TLB inter-
rupt
HiPath 3800, Off-
set 0x1100, Data
TLB Interrupt
Create a trace.
Create a stack dump.
Save a snapshot.
12-027 Instruction TLB in-
terrupt
HiPath 3800, Off-
set 0x1200, In-
struction TLB Inter-
rupt
Create a trace.
Create a stack dump.
Save a snapshot.
12-028 debug interrupt HiPath 3800, Off-
set 0x2000, Debug
Interrupt
Create a trace.
Create a stack dump.
Save a snapshot.
Error Class 15 – Messages Concerning APS Transfer and Saving on Flash
15-000 !Req to switch
over APSXF
Request for APS
transfer.
None
15-001 !APS switched
over KDS ok
APS transfer was
successful.
None
15-002 !APS switched
over def. KDS
APS transfer was
not successful.
Default CDB load-
ed.
Check CDB version.
15-003 !CRC checksum
error
Error in CRC
checksum.
Check APS version.
Transfer APS again.
If the error persists, re-
place the MMC module.
Table 12-7 HiPath 3000 Class B Error Messages