snmpd.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
E-5
Nur für den internen Gebrauch Notes for Editing the File snmpd.cnf
Consequences for the File snmpd.cnf
E.4 Consequences for the File snmpd.cnf
The following entries can be found in the configuration file delivered with the installation.
snmpNotifyEntry icn1 hipath trap nonVolatile
snmpTargetParamsEntry v1Params 0 snmpv1 public noAuthNoPriv nonVolatile
snmpTargetParamsEntry v2Params 1 snmpv2c public noAuthNoPriv nonVolatile
vacmAccessEntry Anyone - snmpv1 noAuthNoPriv prefix CfgProt - CfgProt \
nonVolatile
vacmAccessEntry Anyone - snmpv2c noAuthNoPriv prefix CfgProt - CfgProt \
nonVolatile
vacmAccessEntry SetAnyone - snmpv1 noAuthNoPriv prefix CfgProt CfgProt \
CfgProt nonVolatile
vacmAccessEntry SetAnyone - snmpv2c noAuthNoPriv prefix CfgProt CfgProt \
CfgProt nonVolatile
vacmSecurityToGroupEntry snmpv1 public Anyone nonVolatile
vacmSecurityToGroupEntry snmpv1 private SetAnyone nonVolatile
vacmSecurityToGroupEntry snmpv2c public Anyone nonVolatile
vacmViewTreeFamilyEntry All internet - included nonVolatile
vacmViewTreeFamilyEntry CfgProt internet - included nonVolatile
vacmViewTreeFamilyEntry CfgProt vacmSecurityToGroupTable - excluded \
nonVolatile
vacmViewTreeFamilyEntry CfgProt vacmAccessTable - excluded nonVolatile
vacmViewTreeFamilyEntry CfgProt snmpCommunityTable - excluded nonVolatile
vacmViewTreeFamilyEntry CfgProt usmUserTable - excluded nonVolatile
vacmViewTreeFamilyEntry CfgProt vacmViewTreeFamilyTable - excluded \
nonVolatile
This means that any entries to be made must always be in the following format:
1. Communities
(Definition: There is exactly one read and exactly one write community.)
a) Read Community
snmpCommunityEntry t001 <community-string> public localSnmpID -
- nonVolatile
a) Read Community
snmpCommunityEntry t002 <community-string> public localSnmpID -
- nonVolatile
2. Trap Destinations
snmpTargetAddrEntry <No.> snmpUDPDomain <IP address>:<Port> 100 3
hipath v1Params nonVolatile 255.255.255.255:0 2048