service.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
12-91
Nur für den internen Gebrauch Service
Guided Maintenance
1023 X Socket
not con-
nected
Connection dif-
ficulties - HiPath
3000/5000
server. TCP
connection not
available
Save event
file for er-
ror analy-
sis
Check LAN, ini-
tiate HiPath 3000/
5000 ping.
Restart server if
necessary. Check
HiPath 3000/5000
HIP.
fct HiPath
AllServ
e
1024 CDB
transfer
success-
ful (read)
All frame pages
successfully
read from Hi-
Path 3000/5000
nodes by the
server
Information vsrv HiPath
AllServ
e
1025 CDB
transfer
success-
ful (write)
All frame pages
successfully
written from the
server to all Hi-
Path 3000/5000
nodes
Information vsrv HiPath
AllServ
e
1027 CallAd-
dressTab
le and
NodeIpT-
able
transfer
success-
ful
Successful
transfer of call
address table
and node IP ta-
ble to the sys-
tem by the serv-
er
Information car HiPath
AllServ
e
1028 X Venus
data-
base
closed
Venus data-
base closed
Information vsrv HiPath
AllServ
e
1029 X Venus
Data-
base
started
Venus data-
base started
Information vsrv HiPath
AllServ
e
Table 12-8 Event Viewer Entries for the HiPath 5000 Server