Table 3-35 DIUT2 - Assigning the “Sub-D” Interfaces X10 and X11
Pin Signal Signal description Direction
1 TTIP0 a-wire 120 ohms/75 ohms Output
4 LWLO0_FRONT Fiber optic (data output) Output
5 GND Ground return path for the +5-V
power supply
Input/output
6 SCAN_IN0 Adapter test Input
7 SCAN_IN0 Adapter test Input
8 RTIP0 a-wire 120 ohms/75 ohms Input
9 TRING0 b-wire 120 ohms/75 ohms Output
10 +5 V +5-V power supply Output
11 LWLI0_FRONT Fibre optic (data input) Input
12 GND Ground return path for the +5-V
power supply
Input/output
14 +5 V +5-V power supply Output
15 RRING0 b-wire 120 ohms/75 ohms Input
No other pins used.
Signal Name Connector contact Signal description Direction
+ 5V X1-22, X4-30, X5-30,
X9-28
Power supply unit + 5 V GS Input
U_VOR X5-16, X5-26, X5-36,
X5-18, X5-28, X5-38
Power supply unit + 5 V GS for
hot plug
Input
GND X1-24, X2-26, X3-26,
X4-28, X6-22, X7-24,
X8-24, X9-26
X5-12, X5-22, X5-32,
X5-14, X5-24, X5-34
Earth return for + 5 V GS Input/output
GND X5-23 Earth return for hot plug Not connected
- 48 V X6-04 -48 V power supply unit Not connected
Table 3-36 SIPAC Connector Contact Assignment