boards.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
3-271
Nur für den internen Gebrauch Boards for HiPath 3000
Peripheral boards
Notes on DSP diagnosis
You can use the trace function built into the TMAMF module to diagnose malfunctions or obtain
more precise error analysis. The subminiature D connector provides information about MFC-
R2 signaling. To activate the trace function, you must connect a PC with a terminal emulation
program (such as Microsoft HyperTerminal).
Terminal configuration:
Bits per second = 19,200
Data bits = 8
Stop bit = 1
Parity = none
Flow control = none
Pin assignments of the diagnostic cable
Figure 3-94 Pin Assignments of the TMAMF Diagnostic Cable
PC: RS-232 interface
1
TMAMF: Subminiature D connec-
tor
2 3 4 5
6 7 8 9
12345
6789
1
2
3
5
1
3
2
5