boards.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
3-361
Nur für den internen Gebrauch Boards for HiPath 3000
Options
If ANI4 is properly detected by the system, the green LED is reset (after the initialization of all
system software) and the bottom line of the display on the optiPoint 500 phones appears. This
means that the ANI4 has received system software activation for all four channels.
Table 3-176 ANI4 (for selected countries only) - LED Statuses for Trunk 1
LED Meaning Action
Green LED - Firmware Condition
Off No caller ID signals on the line. Call service provider and
ask if feature is available.
Line is not connected to trunk channel 1. Connect line to trunk chan-
nel 1.
The incoming signal is lower than -36 dBm (as de-
fined in Bellcore SR3004 for the lowest caller ID sig-
nal (space - signal)): the Mitel chip on ANI4 shows no
reaction.
Call service provider and
ask if feature is available.
If so, the signal that appears
on the customer side is too
low (not Bellcore-compliant).
This must be corrected by
the service provider.
The LED or the microcontroller is defective. Replace ANI4 board.
The system has not yet started. Start up system.
On
(but
glowing
weakly)
The Mitel chip interprets the signal on the line as an
FSK carrier signal. However, this could mean that
there is noise or speech on the line, too.
The firmware is in the state of recognition.
On
(for ap-
prox. 1
s)
A valid caller ID signal (correct channel seizure/mark
- bit sequence + valid message byte) on the line is be-
ing recognized at the moment. If a message is not
displayed on the optiPoint 500 telephone, there may
be too much noise on the line. In other words, some
bits in the signal have “tipped over” into the other log-
ical status. The firmware builds the checksum for the
received caller ID message byte and compares this
checksum with the one received.

Table of Contents

Other manuals for Siemens Hipath 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Hipath 5000 and is the answer not in the manual?

Siemens Hipath 5000 Specifications

General IconGeneral
BrandSiemens
ModelHipath 5000
CategoryTelephone
LanguageEnglish

Related product manuals