EasyManuals Logo

Siemens Hipath 5000 Service Documentation

Siemens Hipath 5000
1302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #736 background imageLoading...
Page #736 background image
Startup and Administration HiPath 5000 Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
6-54 HiPath 3000/5000 V9, Service documentation
start_h5.fm
GetAccount
Data record structure
Table 6-7 GetAccount - Data Record Structure
No. Pos. Length Description
1 1-8 8 Date of call end
Format DD.MM.YY, for example “13.09.00”
2 9-16 8 Time of call end
Format hh:mm:ss, for example “14:14:00”
3 17-19 3 Trunk number
right-aligned with leading blanks, for example “ 1”
4 20-22 3 Node ID for HiPath 3000 (matches the configuration in HiPath 3000/
5000 Manager E)
right-aligned with leading blanks
5 23-28 6 Internal extension number
right-aligned with leading blanks
6 29-33 5 Call duration in seconds
7 34-41 8 Call duration
Format hh:mm:ss, for example “00:04:34
8 42-66 25 For incoming calls: external caller number
For outgoing calls: external call number dialed including the call-
by-call number
left-aligned with succeeding blanks
9 67-77 11 Number of tariff units
right-aligned with leading blanks
10 78 1 Call type
1: incoming
2: outgoing (default)
11 79-89 11 Account code ACCT
left-aligned with succeeding blanks
12 90-100 11 MSN used
13 101-105 5 Trunk
right-aligned with leading blanks
14 106-109 4 LCR Selected Route (corresponds to configuration in HiPath 3000/
5000 Manager E)
right-aligned with leading blanks
15 110 1 CR
16 111 1 LF

Table of Contents

Other manuals for Siemens Hipath 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Hipath 5000 and is the answer not in the manual?

Siemens Hipath 5000 Specifications

General IconGeneral
BrandSiemens
ModelHipath 5000
CategoryTelephone
LanguageEnglish

Related product manuals