Commissioning
5.3 Procedure for commissioning via STARTER
Inverter chassis units
Operating Instructions, 07/2016, A5E00331449A
151
Configuring the motor holding brake
Figure 5-24 Configuring the motor holding brake
Under
Holding brake configuration:
choose the appropriate setting for your device
configuration:
0: No motor holding brake being used
1: Motor holding brake like sequence control
2: Motor holding brake always open
3: Motor holding brake like sequence control, connection via BICO
When a motor holding brake is selected, you can also activate the "Extended brake
control" function module.