11
03/2006
11.11Data back-up with VALITEK streamer with the PCU 50
11-257
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
Valitek PST
2
system Verify Connection
Activity Repetitions Connection
Reading Status 500 0
Sending Test Data Blocks 500 0
Receiving Test Data Blocks 500 0
Selected Port : lpt1 Rom Version 85 Revision B <esc>–Abort
Test complete. The connection is functional. Press a key ...
7. You can now, for example, create a complete back-up of all system data. To
do this, select 3, Back-up System means hard disk C.
PLEASE SELECT:
1 Select VALITEK Streamer Type
2 Test Connection to Streamer
3 Back-up System
4 Back-up Userdata
5 Restore from Tape
6 Uninstall MMC102/103 (Delete Files)
7 Return to Main Menu
Your Choice [1,2,3,4,5,6,7]?
The following message appears on the screen:
*** Current Configuration: Valitek PST
2
–M1200 ***
Backing up Partition C: ....
Continue ?
Your Choice: [Y,N]?Y
Start the data back-up by pressing Y.
8. By pressing key 4, Back-up User Data, you opt to create a back-up of the
user data, i.e. batch file C:\TOOLS\BACK_USR.BAT is executed. All archive
files under C:\DH\ARC.DIR are backed up as standard. If you want to back
up additional files, then you must enter other directories in file C:\TOOLS\
BACK_USR.BAT.
PLEASE SELECT:
1 Select VALITEK Streamer Type
2 Test Connection to Streamer
3 Back-up System
4 Back-up Userdata
5 Restore from Tape
6 Uninstall MMC102/103 (Delete Files)
7 Return to Main Menu
Your Choice [1,2,3,4,5,6,7]?4