1-10 7SA6 Manual
C53000-G1176-C133-1
Stub protection: additional stage for fast tripping of faults between the
current transformer and circuit breaker (when the isolator switching
status feed back is available); particularly suited to sub-stations with
1
1
/
2
circuit breaker arrangements.
High Current Fast
Switch-on-to-Fault
Protection
Fast tripping for switch-on-to-fault conditions;
Selectable for manual closure or following each closure of the circuit
breaker;
With integrated line energization detection.
Sensitive Earth
Fault Detection
(optional)
For resonant-earthed or isolated systems with
Detection of displacement voltage
Determination of earth-faulted phases
Sensitive determination of the earth fault direction
Phase displacement correction for current transformers
Automatic
Reclosure
(optional)
For reclosure after single-pole, three-pole or single and three-pole
tripping;
Single or multiple reclosure (up to 8 reclosure attempts);
With separate action times for every reclosure attempt, optionally
without action times;
With separate dead times after single-pole and three-pole tripping,
separate for the first four reclosure attempts;
Controlled optionally by protection start with separate dead times after
single, two and three-pole starting
Optionally with adaptive dead time, phase-to-phase voltage and
reduced dead time
Synchronism and
Voltage Check
(Dead-line /
Dead-bus Check)
(optional)
Checking synchronism conditions before reclosure after three-pole
switching;
Fast measuring of voltage difference U diff of the phase angle
difference
ϕ diff and the frequency difference f diff;
Alternative check of dead-line / dead-bus before reclosure;
Switching under asynchronous network conditions with advance
calculation of the synchro-time possible;
Adjustable minimum and maximum voltage;
Checking synchronism or dead-line / dead-bus also before manual
closure of the circuit breaker, with separate limit values;
Measurement via transformer also possible;
Measuring voltages optionally phase-phase or phase-earth

Table of Contents

Other manuals for Siemens siprotec 7SA6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens siprotec 7SA6 and is the answer not in the manual?

Siemens siprotec 7SA6 Specifications

General IconGeneral
BrandSiemens
Modelsiprotec 7SA6
CategoryRelays
LanguageEnglish

Related product manuals